Sign In | Join Free | My burrillandco.com
Home > ABB Module >

ABB PLC Module System 57160001-ABD/ABW ABB DSTC454 5751017-F Modem Fieldbus

MOORE AUTOMATION LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ABB PLC Module System 57160001-ABD/ABW ABB DSTC454 5751017-F Modem Fieldbus from wholesalers
     
    Buy cheap ABB PLC Module System 57160001-ABD/ABW ABB DSTC454 5751017-F Modem Fieldbus from wholesalers
    • Buy cheap ABB PLC Module System 57160001-ABD/ABW ABB DSTC454 5751017-F Modem Fieldbus from wholesalers

    ABB PLC Module System 57160001-ABD/ABW ABB DSTC454 5751017-F Modem Fieldbus

    Ask Lasest Price
    Brand Name : ABB Module
    Model Number : DSTC454 5751017-F
    Certification : CO.CQ
    Price : inquiry
    Payment Terms : T/T
    Supply Ability : 10 pieces a day
    Delivery Time : today
    • Product Details
    • Company Profile

    ABB PLC Module System 57160001-ABD/ABW ABB DSTC454 5751017-F Modem Fieldbus

    ABB Module DSTC454 5751017-F 57160001-ABD/ABW ABB DSTC454 5751017-F MODEM FIELDBUS Reasonable price


    Product Description:


    IResolution in the PLC system: The measured values are converted with a resolution of
    12 bits, i.e. 11 bits plus sign for voltage and 12 bits without sign for current. The ranges 0...5 V und ±5 V are converted with 10 bits plus sign.the output A 62,00 is only available for the counter. If the output is to use as a normal digital output, it has to Further details can be found in volume 2, chapter 5.1 "General
    information for the use of analog inputs and outputs". In order to make sure, that unused input channels have a defined 0V level, they may be shorted to AGND. Unused inputs must be configured with "unused".
    The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows


    Related Product Recommendation:


    CI531 3BSE003825R13ASC25H705/707KT97B
    CI532V01 3BSE003826R13ASU21C110 LU6278 DCU30/707KT97C
    CI532V02 3BSE003827R13AUA489002B456207KT97
    CI532V02 3BSE003827R13BHE022291R010107KT97B
    CI532V04 3BSE003829R13BHE023784R253007KT97B
    CI540 3BSE001077R13BHE024577R0101 PP C907 BE07KT97B
    CI570 3BSE001440R13BSE001245R1 3BSC640008R107KT97B
    CI590 3BHT340092R13BSE003879R107KT98E2
    CI615 3BHT300024R13BSE011316R1 SDCS-PIN-5207MK92
    CI626A 3BSE005023R13HAC14550-4TC50
    CI630 3BSE011000R13HAC14551-2ICFC16l1
    CI8303HAC17484-8ICSF08D1
    CI854AK01 3BSE030220R13HAC17484-9ICSK20F1-120
    CI857K01 3BSE018144R13HNE00313-1ICSK20F1-230
    CI860 CI860K01 3BSE032444R13HNM09846-1ICSK20F1-24
    CM30/000S0E0/STD3HNP04014-1ICSK20N1
    CMA112 3DDE300013424K1105ICSA04B5
    CMA114 3DDE3000136638910B1 638910B1PS0084ICSE08B5
    CMA121 3DDE3004017944831D07KR31
    CMA132 3DDE30041289AR3007KR31
    CS300E PAC 031-1053-0007KR9107KT31
    07KT98 GJR5253100R027007KR9107MK62
    07KT98 WT9807KR9135NE90
    07KT98 GJR5253100R027007KT9235GS91
    07KT98 WT9807KT9235GS91
    07MK92 GATS110098R016107KT9235DS91
    07MK92 GJR5253300R116107KP9035AB94B
    07NG61R1 GJV3074311R107KT9335AA92C-E
    07NG63R1 GJV3074313R107KT9335EK90
    07PS62R2 GJV3074332R207KT9335EK91
    07SK90R1 GJR5250200R0001ICDG32L135TP90

    Product's Character:


    In case of a configured plausibility monitoring, range underflow and range overflow by 2...3 % result in an error message (FK4, error number 10). Independent of the configured monitoring, the error values +32767 and -32767 are always generated in case of range underflow and range overflow. Exception: In the measuring range of 0...20 mA only the range overflow is Unused inputs must be configured with "unused". The relationship between the analog input signals and the converted numbers is illustrated in the following figures. be made sure, that the high-speed counter is not configured to the operating modes 1 or 2 (see also the chapter "High-speed counter").Features of the analog inputs:The 8 analog inputs are not electrically isolated.The resolution of the A/D converter is 12 bits. Analog signals are conducted in shielded cables (seeThe analog inputs can be configured individually in a lot of different operating modes (even as digital inputs). The configuration is performed by setting certain bits in the system constants KW 86,00 to KW 86,07 as follows



    DSAO120 57120001-EY DSAO 120 Analog Output Module 8 Channels ABB
    DSAO120A 3BSE018293R1 Analog Output Board ABB
    DSAO301 57120001-DZ/4 Analog Output Board ABB
    DSAV110 57350001-E Driver Module Video ABB
    DSAV111 57350001-CN DSAV 111 Video Generator Module ABB
    DSAX110 57120001-PC/5, 57120001-PC/6 DSAX 110 Analog Input/Output Module ABB
    DSAX110A 3BSE018291R1 DSAX 110A Analog Input/Output Module ABB
    DSAX452 5712289-A DSAX 452 BasicUnit - Analog I/O ABB
    DSBB102 57310256-A / 1 Busboard MV 850 ABB
    DSBB107 57310256-BE Bus Board ABB
    DSBB110 57330001E ABB Master Shield Board ABB
    DSBB110A 57330001-Y ABB Master Shield Module ABB
    DSBB120 4898 0002-A Battery Backup Unit ABB
    DSBB170 57310256-DL Bus Board ABB
    DSBB175 57310256-CC/I Bus Board ABB
    DSBBN001-0 Back Plane ABB
    DSBBN002-0 Back Plane ABB
    DSBC110 57310256-E/1 DSBC 110 Bus Termination Module ABB
    DSBC111 57310256-K/1 DSBC 111 Bus Module ABB
    DSBC170 57310256-DB Bus Module ABB

    DSBC172 57310001-KD/5, 57310001-KD DSBC172 Bus Repeater Module ABB
    DSBC172N 3BNP000467R1 Repeater Module ABB
    DSBC173 57310001-KH DSBC 173 Bus Extender S100 I/O Bus ABB
    DSBC173A 3BSE005883R1 Bus Extender S100 I/O Bus ABB
    DSBC173N 3BNP000468R1 Repeater Module ABB
    DSBC174 3BSE012211R1 DSBC 174 Bus Extender Module - S100 I/O Bus ABB
    DSBC176 3BSE019216R1 Bus Extender Board ABB
    DSBSN001 Digital Output Board ABB
    DSCA114 57510001-AA DSCA 114 Communication Board ABB
    DSCA124 57520001-BU Communications Module ABB
    DSCA125A 57520001-CY Communications Board ABB
    DSCA130 57510001-AT DSCA 130 MB200 Communication Board ABB


    The use of the product:

    1.petrochemical,

    2.energy,

    3.transmission and distribution.
    Product's advantages:

    1. Improve efficiency


    2. new and original


    3.1 year warranty


    Our advantages:

    1.open architecture to take advantage of traditional or renewable sources of energy!


    2.emission reduction


    3.Avoid unplanned downtime

    Frequently Asked Questions:

    1. Q: Do you provide warranty for the goods?
    A: Yes, we provide warranty for all the goods from us.


    2.Q:How about the payment terms ?
    A:We frequently use T/T


    3.Q:What about your shipping terms ?
    A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on


    Send your Inquiry details in the Below, Click "Send" Now!

    Contact Information:
    Contact:Miya ( manager)

    Email :sales@mooreplc.com
    Q Q: 2851195450
    Skype: miyazheng520
    Mobile:86-18020776792 ( what's app )

    Product Tags:

    abb plc

      

    advant ocs

      
    Quality ABB PLC Module System 57160001-ABD/ABW ABB DSTC454 5751017-F Modem Fieldbus for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: MOORE AUTOMATION LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)